Teledyne Microwave Solutions


Click below
for pdf

Frequency
(GHz)

Power (W) Duty (%) Max. Typical Gain (dB) Min/Max @ Rated Pout Efficiency (%) Typical Modulation (Control Electrode) Output Connection Weight (lbs/kg) (NTE)
MTG 5082H 2.5 - 8.0 275 100 40/64 23 GRID SC 8/3.6
MEC 5296 2.5 - 7.5 535 100 31/43 28 GRID SC 9/4.1
MEC 5498 2.5 - 7.5 535 100 26/43 28 GRID WRD 250 9.5/4.32
MEC 5497 2.5 - 7.5 630* 100 31/43 37 GRID SC 9/4.1
M5889NO 4.0 - 8.0 250 100 46/59 21 N/A N 9/4.1
MEC 5889 4.0 - 8.0 250 100 46/59 21 GRID N 9/4.1
MTG 5130 5.0 - 11.0 500* 100 40/57 21 FE WRD 475 8/3.6
MEC 5413 6.0 - 18.0 200 100 35/46 20 GRID WRD 650 9/4.1
MEC 5414 6.0 - 18.0 200 100 35/46 20 FE WRD 650 9/4.1
MEC 5423 6.0 - 18.0 250 100 35/46 23 GRID WRD 650 9/4.1
MEC 5424 6.0 - 18.0 250 100 35/46 23 FE WRD 650 9/4.1
MEC 5415 6.0 - 18.0 300 100 35/46 26 GRID WRD 650 9/4.1
MEC 5416 6.0 - 18.0 300 100 35/46 26 FE WRD 650 9/4.1
MEC 5508 6.0 - 18.0 200* 100 26/28 28 FE WRD 650 3/1.36
MEC 5409 6.5 - 18.0 200 100 35/48 20 GRID WRD 650 9/4.1
MEC 5410 6.5 - 18.0 200 100 35/48 20 FE WRD 650 9/4.1
MEC 5421 6.5 - 18.0 250 100 35/45 24 GRID WRD 650 9/4.1
MEC 5422 6.5 - 18.0 250 100 35/45 24 FE WRD 650 9/4.1
MEC 5411 6.5 - 18.0 300 100 35/45 25 GRID WRD 650 9/4.1
MEC 5412 6.5 - 18.0 300 100 35/45 25 FE WRD 650 9/4.1
MEC 5405 7.5 - 18.0 200 100 35/55 22 GRID WRD 750 9/4.1
MEC 5406 7.5 - 18.0 200 100 35/55 22 FE WRD 750 9/4.1
MEC 5419 7.5 - 18.0 250 100 35/55 25 GRID WRD 750 9/4.1
MEC 5420 7.5 - 18.0 250 100 35/55 25 FE WRD 750 9/4.1
MEC 5407 7.5 - 18.0 300 100 35/55 29 GRID WRD 750 9/4.1
MEC 5408 7.5 - 18.0 300 100 35/55 29 FE WRD 750 9/4.1
MEC 5487 8.0 - 18.0 325 100 44/47 32 GRID WRD 750 9/4.1
MEC 5519 11.0 - 18.0 500* 100 53/55 28 FE WRD 750 9/4.1
MEC 5493 18.0 - 26.5 50 100 26/28 20* FE WRD 180 7/3.2
MEC 5493E 18.0 - 26.5 50 100 26/28 20* FE WR 42 7/3.2
MEC 5496 26.5 - 40.0 40 100 35/50 20* FE WRD 180 7.5/3.4

*OVER MAJORITY OF FREQUENCY RANGE - PERFORMANCE MAY BE REDUCED AT BAND EDGES.

Specifications Subject To Change Without Notice
For additional Information contact: Teledyne MEC 
Teledyne MEC TWTs are controlled by the International Traffic in Arms Regulations, and can only be exported via a U.S. Department of State export license. A few model numbers, as so identified, require a U.S. Department of Commerce Export License. They may not be transferred, transshipped on a non-continuous voyage, or otherwise be disposed of in any other country, either in their original form or after being incorporated into other end-items, without the prior written approval of the U.S. Department of State.

 
Teledyne Microwave Solutions  |  11361 Sunrise Park Drive, Rancho Cordova, CA 95742